Three-position Four-way Reversing Valve
Precise Directional Control – Three‑position Four‑way Reversing Valve LSV‑08‑34‑C Hydraulic systems depend on directional valves to control the flow of oil to actuators – cylinders and motors. The three‑position four‑way reversing valve from Flying Bull (Model LSV‑08‑34‑C) is a hydraulic cartridge solenoid directional valve designed to control flow direction within hydraulic systems. It is commonly used in industrial applications – such as hydraulic circuits in construction machinery – where reliable directional switching, low pressure loss, and controlled leakage are essential. The valve is 100% brand new, manufactured in Zhejiang, China, and backed by a 1‑year warranty. Delivery takes 5–7 working days. Product overview – what this valve does This is a hydraulic cartridge valve, OE number LSV‑08‑34‑C. It functions as a three‑position, four‑way hydraulic cartridge solenoid directional valve, designed to control flow direction within hydraulic systems. Three positions means the spool has three discrete positions (center, left, and right). Four ways means the valve has four ports: pressure (P), tank (T), and two work ports (A and B). By shifting the spool, the valve directs oil from the pump to one side of a cylinder while allowing the other side to return to tank – controlling the direction of cylinder movement. Operating pressure and flow range Pressure – Rated for standard hydraulic system pressures, this valve maintains stable internal leakage control between high‑ and low‑pressure chambers under operating conditions, preventing system efficiency loss and overheating. Flow – It must operate within a defined flow range to ensure proper directional switching. Exceeding this range can affect reliability, so actual hydraulic conditions must be matched accordingly. Response time and operating frequency Response time (directional switching and reset): AC solenoid – Typically 0.03–0.05 seconds, with noticeable switching impact. DC solenoid – Typically 0.1–0.3 seconds, with reduced switching impact. Reset time is generally slightly longer than switching time. Operating frequency (switching frequency): Single‑solenoid models typically support up to 60 switching cycles per minute, suitable for most hydraulic system requirements. Durability and service life The valve is supplied as 100% new and includes a one‑year warranty. Manufactured with quality components by a supplier with over 15 years of experience, it ensures reliable performance. Service life depends largely on solenoid type: Wet solenoids typically outlast dry types. DC solenoids generally have longer lifespans than AC solenoids. Hydraulic binding of the spool – especially in high‑pressure systems with extended stationary periods – should be avoided to prevent reset failure and extend service life. Key performance characteristics 1. Reliability – The valve reliably switches when energized and resets when de‑energized, provided it operates within specified pressure and flow ranges. 2. Pressure loss – Due to its small orifice size, pressure loss across the valve can be significant, which should be accounted for in system design. 3. Internal leakage – Some internal leakage occurs between high‑ and low‑pressure chambers across working positions. Leakage must be controlled to prevent reduced efficiency, overheating, and inconsistent actuator operation. Why choose Flying Bull for the three‑position four‑way reversing valve LSV‑08‑34‑C? Direct replacement – Matches LSV‑08‑34‑C specifications. Directional control – Critical for hydraulic cylinder and motor operation. 100% brand new – Not rebuilt or refurbished. 1‑year warranty – Against manufacturing defects. Fast delivery – 5‑7 working days from Zhejiang, China. Flying Bull’s three‑position four‑way reversing valve (LSV‑08‑34‑C) is a reliable, high‑quality replacement for industrial and construction hydraulic systems. Choose Flying Bull for precise directional control.
Product Introduction
Products Description
I. Product Type and Applications
This is a hydraulic cartridge valve, OE number LSV-08-34-C. It functions as a three-position, four-way hydraulic cartridge solenoid directional valve, designed to control flow direction within hydraulic systems. It is commonly used in industrial applications-such as hydraulic circuits in construction machinery-where reliable directional switching, low pressure loss, and controlled leakage are essential.
II. Operating Pressure and Flow Range
Pressure: Rated for standard hydraulic system pressures, this valve maintains stable internal leakage control between high- and low-pressure chambers under operating conditions, preventing system efficiency loss and overheating.
Flow: It must operate within a defined flow range to ensure proper directional switching. Exceeding this range can affect reliability, so actual hydraulic conditions must be matched accordingly.
III. Response Time and Operating Frequency
Response Time (Directional Switching and Reset):
AC solenoid: typically 0.03–0.05 seconds, with noticeable switching impact.
DC solenoid: typically 0.1–0.3 seconds, with reduced switching impact.
Reset time is generally slightly longer than switching time.
Operating Frequency (Switching Frequency):
Single-solenoid models typically support up to 60 switching cycles per minute, suitable for most hydraulic system requirements.
IV. Durability and Service Life
The valve is supplied as 100% new and includes a one-year warranty. Manufactured with quality components by a supplier with over 15 years of experience, it ensures reliable performance.
Service life depends largely on solenoid type-wet solenoids typically outlast dry types, and DC solenoids generally have longer lifespans than AC.
Hydraulic binding of the spool, especially in high-pressure systems with extended stationary periods, should be avoided to prevent reset failure and extend service life.
V. Key Performance Characteristics
Reliability: The valve reliably switches when energized and resets when de-energized, provided it operates within specified pressure and flow ranges.
Pressure Loss: Due to its small orifice size, pressure loss across the valve can be significant, which should be accounted for in system design.
Internal Leakage: Some internal leakage occurs between high- and low-pressure chambers across working positions. Leakage must be controlled to prevent reduced efficiency, overheating, and inconsistent actuator operation.
|
OE NO.: LSV-08-34-C |
|
|
Warranty: 1 YEAR |
Condition:New, 100% Brand-new |
|
Place of Origin:Zhejiang, China |
Ltem:Hydraulic Cartridge Valve
|
|
Brand Name:FLYING BULL |
Quality:High-Quality |
|
Delivery:5-7 Working Days |
Pressure:Ordinary Pressure |

Company Introduction







Frequently Asked Questions (FAQ)
1. What type of valve is this, and what application scenarios is it suitable for?
It is a hydraulic cartridge valve, specifically a hydraulic plug‑in electromagnetic directional valve with three‑position four‑way functionality (OE No.: LSV‑08‑34‑C). It is ideal for medium flow control in hydraulic systems, especially in industrial scenarios (e.g., hydraulic circuits of construction machinery) that require reliable commutation, controlled pressure loss, and leakage management.
2. What are the response time (commutation and reset) and operating frequency of this valve?
Response time – AC solenoids: 0.03–0.05 seconds (large impact). DC solenoids: 0.1–0.3 seconds (small impact). Reset time is slightly longer than commutation time.
Operating frequency – For single‑solenoid valves, the maximum commutation frequency is typically 60 times per minute, meeting regular hydraulic system operation needs.
3. What factors affect the service life of this reversing valve, and how can it be extended?
Service life mainly depends on solenoid type: wet solenoids last longer than dry ones, and DC solenoids outlast AC ones. To extend life, avoid the "hydraulic clamping phenomenon" of the spool (more likely in high‑pressure systems – longer spool stay time increases clamping force, leading to reset failure).
4. What are the product condition and warranty terms for this valve?
The valve is 100% brand new and comes with a 1‑year warranty. Backed by the manufacturer's over 15 years of production experience and high‑quality components, it ensures stable performance in long‑term hydraulic system use.
5. What key performance characteristics should be noted when selecting this valve?
(1) Reliability – Commutates reliably when energized and resets reliably when de‑energized (within specified flow and pressure ranges).
(2) Pressure loss – Large pressure loss occurs due to the small valve port opening.
(3) Internal leakage – Leakage from high‑pressure to low‑pressure chambers (at specified pressure) must be controlled to avoid reduced system efficiency, overheating, or actuator malfunctions.
6. What is the standard delivery time, and is custom service available for bulk orders?
Standard delivery takes 5‑7 working days. Custom services are provided to meet specific B2B needs, such as batch customization for downstream clients in construction machinery maintenance or hydraulic system parts distribution.
7. What is the difference between a three‑position four‑way valve and a two‑position valve?
A two‑position valve has two states (energized or de‑energized) – it switches between two positions. A three‑position valve has a center position (spring‑centered) with three possible spool positions – center (neutral), left, and right. Three‑position valves allow more control options, such as blocking all ports in the center position for load holding.
8. Does the three‑position four‑way reversing valve come with a warranty?
Yes. Flying Bull provides a 1‑year warranty against manufacturing defects. Damage caused by contamination (dirty oil), incorrect installation, overpressure, voltage issues, or physical damage is not covered.
9. Is this valve a direct replacement for the original LSV‑08‑34‑C?
Yes. The LSV‑08‑34‑C is manufactured as a direct replacement for the original three‑position four‑way reversing valve. It matches the original cavity size, flow characteristics, pressure rating, voltage, and connector type. Always verify your original part number before ordering.
10. What should I do if the valve does not shift (commutate) after installation?
(1) Check electrical power – verify voltage at the connector when the solenoid should be energized. (2) Check coil resistance with a multimeter (compare to specification). (3) Check hydraulic pressure – ensure pilot pressure (if applicable) is within the required range. (4) Check for contamination – a stuck spool may need cleaning or replacement. (5) If all else fails, contact your supplier for support.
Hot Tags: three-position four-way reversing valve, China three-position four-way reversing valve manufacturers, suppliers, factory, liebherr solenoid valve replaced, volvo solenoid valve replaced, hydraulic cartridge valve, wirtgen solenoid valve replaced, lovol solenoid valve replaced, doosan solenoid valve replaced
You Might Also Like
Send Inquiry